Abstract

A low Earth orbit satellite experiences roughly 5500 eclipse charge–discharge cycles per year. We model cycle life to 80% state of health against depth of discharge (DoD), charge cutoff voltage and temperature, and explain why 1P PocketQubes run at 5–15% eclipse DoD with a 4.10 V ceiling.

Contents

5500 eclipses per year#

In a orbit ( period), a spacecraft enters Earth's shadow times every day—about charge–discharge cycles per year[1]. Consumer lithium-ion pouch and cylindrical 18650 cells are rated for deep cycles ( ). Surviving two to three years in requires restricting the eclipse depth of discharge to a small fraction of nominal capacity[2]:

For an eclipse load lasting (), the energy drawn per eclipse is . Against a single , () 18650 cell or a () LiPo pouch cell, this corresponds to or [3].

18650 / pouch Li-ion cycle life and 3-year capacity retention in a 525 km LEO orbit (15.15 orbits/day) vs. depth of discharge and charge cut-off voltage
DoD per eclipseCharge cut-off (V)Usable energy / 9.25 Wh cell (Wh)Cycles to 80% SoHYears to 80% SoH3-year retention
10%4.100.9324,4294.484.4%
15%4.101.3912,8732.376.4%
20%4.101.858,1711.568.3%
20%4.201.854,0850.750.2%
30%4.102.784,3060.851.9%
45%4.204.161,1340.240.0%

Charge-voltage derating and the 0 °C plating threshold#

Two operational limits govern cell longevity in orbit[1]:

  1. End-of-charge voltage ceiling: Lowering the maximum charge termination voltage from to sacrifices about of initial capacity but nearly doubles the number of cycles before solid-electrolyte interphase (SEI) growth reduces state of health to .
  2. Sub-zero charging inhibit: Charging a graphite-anode Li-ion cell below causes metallic lithium plating on the anode, permanent capacity loss and internal short-circuit risk. Because a has a near , the battery exits eclipse near its coldest point—precisely when solar arrays hit peak illumination. An EPS hardware comparator or thermistor-gated charge switch must block charging or divert solar power to a Kapton heater until cell temperature exceeds [2].

References

  1. [1]NASA Small Spacecraft Systems Virtual Institute. (2026). Power. State-of-the-Art of Small Spacecraft Technology (2026 edition), Chapter 3. NASA Ames Research Center.nasa.gov(accessed 20 October 2026)
  2. [2]nadir lab. (2026). PocketQube picosatellites: A review of standards, mission trends and miniaturization constraints, with lessons learned from Grizu-263A, Türkiye’s first PocketQube [Preprint]. nadir lab.Read on nadir lab.
  3. [3]Bouwmeester, J., Radu, S., Uludag, M. S., Chronas, N., Speretta, S., Menicucci, A., & Gill, E. K. A. (2020). Utility and constraints of PocketQubes. CEAS Space Journal, 12(4), 573–586.doi:10.1007/s12567-020-00300-0

Cite this article

@misc{nadirlab2026pocketqube,
  author       = {{nadir lab.}},
  title        = {{The 1P battery: capacity, depth of discharge and cycle life}},
  year         = {2026},
  month        = oct,
  howpublished = {nadir lab. nadir lab. technical note SQ-TN-2026-012},
  url          = {https://nadirlab.space/en/articles/pocketqube-battery-dod-cycle-life/},
  language     = {english},
  note         = {Licence: CC BY 4.0}
}
DOI
Not assigned
Identifier
SQ-TN-2026-012
Licence
CC BY 4.0